Skip to content
Unmarked laboratory glassware and a notebook on a research desk.

A Comparison of Different Approaches for Characterizing Microplastics in Selected Personal Care Products

A methods comparison used selected toothpastes and facial scrubs labeled as containing polyethylene to compare counts and size distributions across analytical approaches.

Updated 2026-10-22

A methods comparison used selected toothpastes and facial scrubs labeled as containing polyethylene to compare counts and size distributions across analytical approaches.

Source details

Kofi O. Renner, Helen A. Foster, Edwin J. Routledge, Mark D. Scrimshaw. Environmental Toxicology and Chemistry. 2022.

DOI: 10.1002/etc.5057

Findings

A methods comparison used selected toothpastes and facial scrubs labeled as containing polyethylene to compare counts and size distributions across analytical approaches.

Scroll horizontally for methods and limitations.

EndpointSource-reported resultLocator
Selected PE-containing facial scrub FS224.9 × 10⁶ particles per 100 gPDF p. 5 Table 2; pp. 3-4 methods
Facial scrub FS220 to 423 µmPDF p. 5 Table 2; p. 3 methods

Methods and scope

Warm-water dispersion, salt density separation, centrifugation and aliquot counting. Light microscopy, laser diffraction and imaging flow cytometry measured different size features/windows. Ten randomly selected fragments per product subjected to µFTIR, confirming PE. Complete extraction blanks analyzed; no particles seen by microscopy/laser diffraction, but imaging flow cytometry blanks high enough to prevent quantification of most products. No reference-material recovery validation; aim was comparison of counting methods.

What this source can support

Supports product-code-specific light-microscopy numbers and method-dependent size distributions. It does not support treating all flow-cytometry events as plastic.

Four deliberately PE-containing products; not prevalence or current-market survey. Chemical identity checked on subsample, not every counted object. Counts extrapolated from aliquots. Table 2 TP2 differs from narrative and flow-cytometry FS2 differs between Table 4 and narrative; accepted Table 2 facial-scrub value only. Primary volume year 2022 despite online publication/filename 2021. No dermal uptake or clinical outcomes measured.

Cosmetics and personal care

Reported values and source locations

Reported valueMeasurement basisConditions and size contextOriginal document location
24.9 × 10⁶ particles per 100 gTable point estimate; microscopy triplicate workflowFacial scrub FS2 after extraction; light-microscopy enumeration, no observed microscopy blank particles
20-423 µm observed FS2 light-microscopy range
PDF p. 5 Table 2; pp. 3-4 methods
20 to 423 µmObserved range, not instrument operating rangeFS2 light-microscopy size analysis, longest dimension
Observed microscopy range
PDF p. 5 Table 2; p. 3 methods
Source provenance

Primary PDF SHA-256: e13c6d65105256aeab722823f38bc1c3206007f2e3b87bc573ce5c275dd672da

The source record identifies the scope and limits of the primary-document review. Follow the DOI or official source link for the original document; this site does not redistribute the PDF.

Cite this page

Microplastics Reference Library. A Comparison of Different Approaches for Characterizing Microplastics in Selected Personal Care Products. Updated 2026-10-22. https://microplasticsindex.com/sources/s-e13c6d651052

Search the library